1. High-speed corrosion in sheet piling caused by bacteria
A significant issue was identified in a saltwater environment: lightning-fast corrosion on sheet piling. In just one decade, the 8 mm thick sheet piling had completely disappeared in some places, leading to subsidence. This rapid corrosion suggested that microbiologically influenced corrosion (MIC) was likely.
Research approach
To uncover the causes of the rapid corrosion, a team of experts was called in. A diving team filmed the suspected locations of the sheet piles and took samples of the corroded parts. These samples were then subjected to thorough analysis in our lab.
Results Visual Inspection: clear presence of pitting corrosion, typical of MIC.
- Microbiological Analysis: in de samples sulphur-related bacteria, sulphate-reducing and sulphate-oxidising bacteria, and iron-reducing bacteria were found.
- Chemical Analysis: the composition of the salt harbour water promotes microbial growth with sufficient nutrients such as organic and inorganic carbon, and sulphur.
- Mineralogical Analysis: the results of the mineralogical and chemical examination of the corrosion products support the diagnosis of MIC. The results do not rule out the possibility of other corrosion processes.
Conclusion and Advice
The study results confirmed that the rapid corrosion of the sheet piling was due to MIC, with a high corrosion rate indicating Accelerated Low Water Corrosion (ALWC). This is more often seen in places where the water level is highly fluctuating. Given the adverse environmental conditions, such as the presence of several species of MIC bacteria and sufficient nutrients, we created an appropriate mitigation plan for this site to limit further damage. This included special coating and cathodic protection.